ENERENT Slovakia

Rent | Buy Mobile Heaters & Cooling Technology

Quick, Easy, Fair

 

ENERENT is your expert for mobile energy solutions for rent or purchase. With our brands HOTMOBIL and mobiheat, we are leaders in the rental and sale of mobile heating and steam units. With our cooling brand NOVACHILL, we offer you the most advanced air conditioning and cooling technology to meet your needs for process cooling and refrigeration.

Our distribution partner, EBECO, is your regional contact for Slovakia, ensuring smooth delivery and processing.

Mobile Heat - Purchase | Rent

 

Examples of Use - depending on the power class, you will find here:

  • Electric Heaters up to 40 kW: classic products for screed drying or for temporary heating during boiler replacement and renovation
  • Mobile Heating Units up to 320 kW: emergency heating for larger buildings, construction site drying, screed drying, process heat, or mobile heat for biogas plants. 
  • Mobile Heating Units 550 KW up to 1.500 kW: ideal for medium to large-scale industrial applications, providing reliable process heat, supporting large-scale temporary heating needs
  • Mobile Heating Containers up to 2.500 kW: district heating, large projects, and process heat supply

Technical data

Accesories

  • Dimensions and Weights
    • Weights (kg): 58
    • Height (mm): 1220
    • Length/Depth (mm): 580
    • Width (mm): 600
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Max. Heating Temperature (°C): 80
    • Heating Capacity (kW): 3 / 11 / 19
    • Heating Programs: 6 fixed + custom programs
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 16A / 230V | CEE 16A / 400V | CEE 32A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 5.5
    • Max. Flow Rate Circulation Pump (m³/h): 3
    • Hydraulic Connection Heating: Bayonet lock
    • Nominal Diameter Heating Connection: DN25
    • Nominal Pressure: PN3
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 2.8
    • Safety Valve (bar): 3

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 70
    • Height (mm): 1260
    • Length/Depth (mm): 585
    • Width (mm): 670
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Max. Heating Temperature (°C): 80
    • Heating Capacity (kW): 8 / 16 / 40
    • Heating Programs: 6 fixed + custom programs
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 16A / 400V | CEE 32A / 400V | CEE 63A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 6.5
    • Max. Flow Rate Circulation Pump (m³/h): 5.5
    • Hydraulic Connection Heating: Bayonet lock
    • Nominal Diameter Heating Connection: DN25
    • Nominal Pressure: PN3
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 2.8
    • Safety Valve (bar): 3

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance

Technical data

Accesories

  • Dimensions and Weights
    • Weights: 750
    • Weights (kg): 750
    • Height (mm): 1850
    • Length/Depth (mm): 2700
    • Width (mm): 1500
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 120
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): 50 - 70
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Oilburner
    • Oil consumption at full load (l/h): 7
  • Sonstiges
    • Tank volume (l): 750
    • Usable tank volume (l): 710
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 16A / 230V
  • Hydraulics
    • Max. Pump Head (mWs): 12
    • Max. Flow Rate Circulation Pump (m³/h): 10.5
    • Hydraulic Connection Heating: Storz
    • Nominal Diameter Heating Connection: DN32
    • Nominal Pressure: PN3
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 2.8
    • Safety Valve (bar): 3

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights: 1800
    • Weights (kg): 990
    • Height (mm): 2010
    • Length/Depth (mm): 3440
    • Width (mm): 1525
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 120
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): 80 - 110
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Oilburner
    • Oil consumption at full load (l/h): 10
  • Sonstiges
    • Tank volume (l): 920
    • Usable tank volume (l): 874
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 16A / 230V
  • Hydraulics
    • Max. Pump Head (mWs): 12
    • Max. Flow Rate Circulation Pump (m³/h): 10.5
    • Hydraulic Connection Heating: Storz
    • Nominal Diameter Heating Connection: DN50
    • Nominal Pressure: PN3
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 2.8
    • Safety Valve (bar): 3

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights: 3000
    • Weights (kg): 1680
    • Height (mm): 3690
    • Length/Depth (mm): 4540
    • Width (mm): 2030
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 200
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): 73 - 160
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Oilburner
    • Oil consumption at full load (l/h): 15.5
  • Sonstiges
    • Tank volume (l): 1000
    • Usable tank volume (l): 950
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 16A / 230V
  • Hydraulics
    • Max. Pump Head (mWs): 16
    • Max. Flow Rate Circulation Pump (m³/h): 40
    • Hydraulic Connection Heating: Storz
    • Nominal Diameter Heating Connection: DN50
    • Nominal Pressure: PN3
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 2.8
    • Safety Valve (bar): 3

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights: 3000
    • Weights (kg): 2170
    • Height (mm): 2850
    • Length/Depth (mm): 5260
    • Width (mm): 2250
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 250
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): 300
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Oilburner
    • Oil consumption at full load (l/h): 29.9
  • Sonstiges
    • Tank volume (l): 1500
    • Usable tank volume (l): 1425
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 16A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 16
    • Max. Flow Rate Circulation Pump (m³/h): 40
    • Hydraulic Connection Heating: Storz
    • Nominal Diameter Heating Connection: DN50
    • Nominal Pressure: PN3
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 2.8
    • Safety Valve (bar): 3

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance

Technical data

Accesories

  • Dimensions and Weights
    • Weights (kg): 6130
    • Height (mm): 3250
    • Length/Depth (mm): 6060
    • Width (mm): 2550
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 300
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): Oil 240-600/Gas 110-600
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Dual-fuel burner
    • Oil consumption at full load (l/h): 62
    • Gas connection: 1 ½“ Inlet thread
    • Gas connection pressure: min. 50 mbar, max. 300 mbar
  • Sonstiges
    • Tank volume (l): 4800
    • Usable tank volume (l): 4560
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 32A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 17
    • Max. Flow Rate Circulation Pump (m³/h): 57
    • Hydraulic Connection Heating: Flange
    • Nominal Diameter Heating Connection: DN65
    • Nominal Pressure: PN6
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 5.8
    • Safety Valve (bar): 6

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 6930
    • Height (mm): 3500
    • Length/Depth (mm): 6060
    • Width (mm): 2550
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 300
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): Oil 400-1000 / Gas 150-1000
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Dual-fuel burner
    • Oil consumption at full load (l/h): 104
    • Gas connection: 1 ½“ Inlet thread
    • Gas connection pressure: min. 50 mbar, max. 300 mbar
  • Sonstiges
    • Tank volume (l): 4800
    • Usable tank volume (l): 4560
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 63A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 24
    • Max. Flow Rate Circulation Pump (m³/h): 68
    • Hydraulic Connection Heating: Flange
    • Nominal Diameter Heating Connection: DN100
    • Nominal Pressure: PN16
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 5.8
    • Safety Valve (bar): 6

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 9950
    • Height (mm): 3950
    • Length/Depth (mm): 6060
    • Width (mm): 2550
  • Heating
    • Min. Heating Temperature (°C) : 20
    • Diameter of exhaust chimney (mm): 450
    • Max. Heating Temperature (°C): 90
    • Heating Capacity (kW): Oil 800-2500 / Gas 350-2500
    • Heating Programs: 6 fixed + custom programs
  • Performance
    • Burner: Dual-fuel burner
    • Oil consumption at full load (l/h): 250
    • Gas connection: Flange DN 80 / PN 16
    • Gas connection pressure: min. 50 mbar, max. 300 mbar
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 63A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 24
    • Max. Flow Rate Circulation Pump (m³/h): 160
    • Hydraulic Connection Heating: Flange
    • Nominal Diameter Heating Connection: DN100
    • Nominal Pressure: PN16
    • Min. Operating Pressure (bar): 1
    • Max. Operating Pressure (bar): 5.8
    • Safety Valve (bar): 6

Accesories

up to 40 kW

  • Air Heater
  • Fresh Water Station
  • System Separator

up to 2,500 kW

  • System Separator
  • Ventilation Unit
  • Air Heater
  • Fuel Tank System
  • Silencer
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance

Mobile Air Conditioning & Cooling Technology - Purchase | Rent

 

Examples of Use - depending on the power class, you will find here:

  • Split Air Conditioning Units up to 8 kW: classic products for cooling office spaces or small storage areas
  • Mobile Chillers up to 80 kW: cooling for offices, storage areas, or events. 
  • Mobile Cooling Containers up to 550 kW: industrial cooling, server room cooling, process cooling for businesses, or climate control for large buildings.

Technical data

Accesories

  • Dimensions and Weights
    • Weights (kg): 117
    • Height (mm): 1070
    • Length/Depth (mm): 420
    • Width (mm): 852
  • Cooling
    • Min. Cooling Temperature (°C): 8
    • Max. Cooling Temperature (°C): 35
    • Max. Ambient Temperature (°C): 0 °C - +40 °C
    • Refrigerant: R407C
    • Refrigerant Charge: 0,88 kg
    • GWP Value: 1774
  • Performance
    • Airflow Volume (m³/h): 1310
    • Cooling Capacity: 7
  • Electrical
    • Electrical Connection: Protective contact plug / 230V
  • Hydraulics
    • Max. Pump Head (mWs): 10
    • Nominal Diameter Cooling Connection: DN15
    • Hydraulic Connection Cooling: Quick coupling

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 117
    • Height (mm): 1070
    • Length/Depth (mm): 420
    • Width (mm): 852
  • Cooling
    • Min. Cooling Temperature (°C): 8
    • Max. Cooling Temperature (°C): 35
    • Max. Ambient Temperature (°C): 0 °C - +40 °C
    • Refrigerant: R407C
    • Refrigerant Charge: 0,88 kg
    • GWP Value: 1774
  • Performance
    • Airflow Volume (m³/h): 1310
    • Cooling Capacity: 7
  • Electrical
    • Electrical Connection: Protective contact plug / 230V
  • Hydraulics
    • Max. Pump Head (mWs): 10
    • Nominal Diameter Cooling Connection: DN15
    • Hydraulic Connection Cooling: Quick coupling

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance

Accesories

  • Dimensions and Weights
    • Weights (kg): 647
    • Height (mm): 2330
    • Length/Depth (mm): 1370
    • Width (mm): 1770
  • Cooling
    • Max. Ambient Temperature (°C): 7 °C - +32 °C
    • Refrigerant: R410A
  • Performance
    • Cooling Capacity: 20.48
  • Electrical
    • Electrical Connection: CEE 32A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 27.7

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 1175
    • Height (mm): 2400
    • Length/Depth (mm): 1310
    • Width (mm): 2670
  • Cooling
    • Max. Ambient Temperature (°C): 7 °C - +32 °C
    • Refrigerant: R410A
  • Performance
    • Cooling Capacity: 48.9
  • Electrical
    • Electrical Connection: CEE 63A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 32

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 1260
    • Height (mm): 2050
    • Length/Depth (mm): 2620
    • Width (mm): 1620
  • Cooling
    • Min. Cooling Temperature (°C): -15
    • Max. Cooling Temperature (°C): 15
    • Max. Ambient Temperature (°C): -5 °C - +43 °C
    • Refrigerant: R454B
    • Refrigerant Charge: 9 kg
    • GWP Value: 466
    • EER value: 2.73
  • Performance
    • Cooling Capacity: 72
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 63A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 13
    • Max. Flow Rate Circulation Pump (m³/h): 12
    • Min. Operating Pressure (bar): 2
    • Max. Operating Pressure (bar): 5
    • Nominal Diameter Cooling Connection: DN65
    • Hydraulic Connection Cooling: Flange

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance

Technical data

Accesories

  • Dimensions and Weights
    • Weights (kg): 1970
    • Height (mm): 2150
    • Length/Depth (mm): 4200
    • Width (mm): 1620
  • Cooling
    • Min. Cooling Temperature (°C): -15
    • Max. Cooling Temperature (°C): 15
    • Max. Ambient Temperature (°C): -5 °C - +43 °C
    • Refrigerant: R454B
    • Refrigerant Charge: 15 kg
    • GWP Value: 466
    • EER value: 2.89
  • Performance
    • Cooling Capacity: 156
  • Electrical
    • Protection Class: IP44
    • Electrical Connection: CEE 125A / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 14
    • Max. Flow Rate Circulation Pump (m³/h): 27
    • Min. Operating Pressure (bar): 2
    • Max. Operating Pressure (bar): 5
    • Nominal Diameter Cooling Connection: DN100
    • Hydraulic Connection Cooling: Flange

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance
  • Dimensions and Weights
    • Weights (kg): 4000
    • Height (mm): 2780
    • Length/Depth (mm): 3660
    • Width (mm): 2400
  • Cooling
    • Max. Ambient Temperature (°C): 7 °C - +32 °C
    • Refrigerant: R410A
  • Performance
    • Cooling Capacity: 333.4
  • Electrical
    • Electrical Connection: 265A Sible Core / 400V
  • Hydraulics
    • Max. Pump Head (mWs): 30.9

Accesories

  • Ventilation Units
  • Chillers
  • Drive-over Ramp
  • Remote Monitoring / Remote Maintenance

Distribution Partner Slovakia: EBECO

Peter Boda - ebeco

Peter Boďa

E-Mail: [email protected]
Phone+421907 802 512

Adress: 

EBECO, s. r. o.
Závodná 958
027 43 Nižná

 

 

 

Professional Consultation:
Mon: 08:00 AM to 05:00 PM
Tue: 08:00 AM to 05:00 PM
Wed: 08:00 AM to 05:00 PM
Thu: 08:00 AM to 05:00 PM
Fri: 08:00 AM to 04:00 PM


Emergency Service: 
24-hour emergency availability

How to Find Us:
 

 

 

Frequently Asked Questions About Mobile Energy Centers

 

What are the most common applications for mobile heating solutions?


Mobile heating solutions are commonly used in construction projects, especially for screed drying and building heating, at events & festivals for heating or hot water supply, in emergencies for heating failures and replacements, in agriculture for frost protection, and in industrial facilities for temporary heat supply during production processes. For all these applications, we offer optimal modern mobile heating units.

 

What are the advantages of renting mobile heaters compared to purchasing them?


Renting mobile heaters offers financial flexibility, eliminates high upfront costs, and reduces maintenance efforts. It also allows for quick availability and adaptation to short-term needs and projects.

 

 

How do I get a quote for my mobile heating or cooling system?


To receive a quote, please contact us by phone, email, or simply request a quote online using one of the "Request Offer" buttons. We will promptly address your request, and our team will provide you with a customized offer for your mobile heating solution. If you have any further questions, we are always here to help you.

 

How long does it take for delivery? Can I pick it up myself?


Delivery of your mobile heating or cooling system usually takes place within 48 hours after the order is placed. Self-pickup is also possible at our location mentioned above; please inform us in advance so we can prepare your order for collection.

 

Personally here for you

Consultation on mobile heating or cooling systems | SLOVAKIA

As your contact person in Slovakia, I will be happy to help you.

Phone:

+421907 802 512

E-Mail:

[email protected]